Flame Retardant Pre Filter Media

Send inquiry

Features

Applications

It is mainly used for work environments and air ventilation systems with strict fire protection requirements.
Technical Parameters

Main components

Flame retardant polyester fiber(PET

Filtration class

G2、G3、G4(EN779)

Filter object

Coarse dust and foreign matter≥5μm

Average weighting efficiency

90%(ASHRAE52.1-1992)

Final resistance(Pa)

250

Smoke density

≤200(TB/3237)

Oxygen index

≥32TB/3237)

Flammable level(import)

class3(JACA No.11A-2003)

Flammable level

S4(DIN5510-2)

Drop grade

ST2(DIN5510-2)

Smoke level

SR2(DIN5510-2)

Temperature resistance

≤100℃

Temp. Short peak

120℃

Humidity resistance 

≤100%


Specifications

Model

Standard Size

Thickness

(mm)

Weight

(g/m²)

Dust holding 

capacity

Rated

 air velocity

(m/s)

CMH

I.N.P

(Pa)

F.N.P

(Pa)

Remark

RT-F10

1m*20m
2m*20m

10mm

150

400

2m/s

7200

20

200

Domestic

RT-F15

1m*20m
2m*20m

15mm

180

500

2m/s

7200

23

200

Domestic

RT-F20

1m*20m
2m*20m

20mm

200

580

2m/s

7200

25

250

Domestic

RT-PS600N

1.6m*20m
2m*20m

20mm

450

600

2m/s

7200

65

250

Import

RT-PS400N

1.6m*20m
2m*20m

15mm

300

550

2m/s

7200

35

250

Import

RT-PS300N

1.6m*30m
2m*30m

10mm

250

500

2m/s

7200

30

220

Import

RT-PS150N

1.6m*30m
2m*30m

8mm

100

400

2m/s

7200

20

220

Import

Note: other specifications can be customized according to requirements.